New module "Event display" and new macro "reconQltyMonitor" with calibrated config_2017offline.dat file
What's new
-
The drift chamber calibration parameters "tref_offset", "wire_offset", "weight" are no more hard coded into anaGm2.
HandleDC.cxx
now read from external fileconfig.dat
throughParameterManager
class. So that we could easily do the iteration of calibration -
A new module
eventDisplay.cxx
is added to output DC hit information (fired wire, plane no., TDC value, TDC width, drift distance, is best fit hits or not, etc) and track fit information (track slope, track position, fit confidence level, isGoodEvent etc). These output inforamtion will be stored in a new tree file calledeventdisptree{runnum}all.root
. A flag "EventDispTree_create" inconfig.dat
file could be used to toggle this module on or off. -
A new macro
reconQltyMonitor
is added. It will read theeventdisptree{runnum}all.root
files and output a histograms root file for inspecting track reconstruction quality (confidence level distribution, residual distribution, TDC value distribtuion and drift distribution by wires, etc). Scripts for merging output files sample by sample are also attached. -
The DC planes misalignment calibration (up till iteration 3) was done using
reconQltyMonitor
macro. Calibration result was saved in config_2017offline.dat files (wire_offsets and weights).
What will be in next merge request
- The macro
yield.C