- Nov 06, 2009
- Nov 05, 2009
-
-
deserevi authored
* Scorer scheme has been updated for Gaspard and S1 detector + General scorers of the NPTool package are used whenever possible
-
- Nov 04, 2009
- Nov 03, 2009
-
-
deserevi authored
+ Target.{hh,cc} class now has a method returning the target material + VEventGenerator.{hh,cc} class now returns the effective thickness of target seen by the beam before interaction (method CalculateBeamInteraction) + Propagate these changes in the different EvenGenerators * Update Gaspard documentation
-
- Nov 02, 2009
- Oct 26, 2009
-
-
matta authored
- Everything is now done in one single class, TMust2Physics
-
matta authored
- Adding AddParameterToCalibrationManager - ReadCalibrationFile should desapear soon
-
matta authored
* Fixing stuff in CalibrationManager - Now if the calibration parameter is not found, the raw value is return without warning, wich is good for simulation
-
- Oct 22, 2009
- Oct 21, 2009
-
-
matta authored
- Now every volume is independents and have is own name - enable pad number function in MUST2 * Adding data to Match_SiLI_Si function in TMust2Physics - according to geometry of detector
-
matta authored
* Little improvment on MUST2 scorer - Map for X,Y and Pad/cristalNumber are now G4int instead of G4double - StripPitch is now a private member of X and Y scorer and is no longer calculated at every event * Adding some file that should be here like the Dummy detector, the ThinSiData or the DummyDetector.detector input file
-
matta authored
-
matta authored
* Progress on MUST2 Physics improvement
-
matta authored
- Algo is now looking at the two last caracter of the volume name and checking if there is one or two number. - Specifying if the scorer is applied to SiLi or CsI is no longer needed * Changing cut value in PhysicsList to 1000pc to avoid warning at compilation
-
- Oct 20, 2009
-
-
matta authored
- Algo need to be fixed because it work only if the array of telescope is under 10
-
- Oct 19, 2009
-
-
deserevi authored
+ finish the NPSimulation part of the documentation
-
matta authored
- Default value for second argument is now in .hh file instead of .cxx file so last argument could be ommited
-
matta authored
- Wrong detector name was given, problem fixed * Setting a hi-cup on secondaries - There is no more secondaries generated (especially e- in the cryo target)
-
- Oct 16, 2009
-
-
matta authored
* Fixing comment in some detector
-
matta authored
-This class describe a simple Dummy Detector : a simple cylinder of predifined material. user can choose to place it where he want using spherical coordinate and choose between two naterial * Updating comment in ThinSi detector (NPS)
-
matta authored
-
matta authored
- Wrong token sequence is no more issued when a comment is insert within the input file * Adding comment support for AnnularS1
-
- Oct 15, 2009
-
-
matta authored
- General Scorer now use the TrackID+DetNbr index system, ensuring more flexibility. - Plastic,MUST2 and ThinSi use the same system and rely on General Scorer * Naming Convention of Detector Volume is define - Volume name should be : DetectorNameX_SubPart - This insure compatibility with the General Scorer * Correcting Bug: if no target the Transfert and TransfertToReasonance method crashed - Fixed by adding a test on the target address * NB: Further test to be made on Gaspard to check everything is fine
-
- Oct 14, 2009
- Oct 12, 2009
- Oct 09, 2009
-
-
deserevi authored
-
- Oct 02, 2013